Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5
Button
Standard display (Fig. 4.1 on p. 3)
Esc
Operation
Selects the operating mode (see Chap. 5 on p. 4)
Menu
Jumps to menu
Shifts the heating curve downwards (colder)
Shifts the heating curve upwards (warmer)
Tab. 4.1: Operator button functions

5 Operating Modes

6 different operating modes can be selected using the button
(Modus). The operating mode can be changed each time the
button is pressed in the order shown below.
COOLING
SUMMER
AUTO
VACATION
(lower operation)
PARTY
(daytime operation)
2nd heat generator
(HG2)
E-4
No action
No action
The system operates in cooling operation. The individual control functions are active.
Only domestic hot water and swimming pool water are heated up in the SUMMER operating
mode. Space heating is not activated. Antifreeze (frost protection) is ensured.
The heat pump operates in automatic operation. DHW heating and heating are activated
according to priority. The heat pump and the 2nd heat generator are switched on or off as
required.
A lowering of the heating characteristic curves is activated in the VACATION operating mode.
The function is independent of the relevant timing, but the lower values set for this function still
apply. The duration of the VACATION operating mode can be set in the menu "1 Settings –
Operation – Vacation mode". After this time period has elapsed, the system switches
automatically back to automatic operation again.
A programmed lowering of the heating characteristic curves is overridden in the PARTY operating
mode. The duration of the PARTY operating mode can be set in the menu "1 Settings –
Operation – Party mode". After this time period has elapsed, the system switches automatically
back to automatic operation again.
The heat pump is switched off in this operating mode and the entire heat supply is provided by
the 2nd heat generator (HG2). This is the immersion heater in mono energy systems. In bivalent
systems it is the oil or gas heating.
Change of setting (Chap. 8 on p. 5)
Exits the menu and returns to the main display
Returns from a submenu
Exits a setting without saving changes
No action
No action
Scrolls downwards between menu items on one level
Changes a setting in a downward direction
Scrolls upwards between menu items on one level
Changes a setting in an upwards direction
Selects a setting in the corresponding menu item
Exits a setting and saves changes
Jumps to a submenu
NOTE
Heat pump operation block
The heat pump is blocked in the 2nd heat generator operating mode.
Heating operation and DHW preparation in mono energy systems is
carried out using electric heating elements. In the case of bivalent
systems, the 2nd heat generator is used.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis