8 Causes of faults and remedies

Fault
Position skips
of the measuring
system
Printed in the Federal Republic of Germany
07/13/2006
Cause
Remedy
Vibrations, impacts and shocks are dampened with "shock
Strong vibrations
modules". If the error recurs despite this measure, the
measuring system must be replaced.
Electrical faults
Perhaps isolated flanges and couplings made of plastic
EMC
help against electrical faults, as well as shielded cables.
Extreme axial and
Couplings prevent mechanical stress on the shaft. If the
radial load on the
error still occurs despite this measure, the measuring
shaft may result in a
system must be replaced.
scanning defect.