4 Technical data

The information specified in the Technical Data refers to the TR standard devices.
The nameplate and any datasheet included with the device are therefore to be
observed !
All dimensions are to be found in the customer-specific drawings.

4.1 Electrical characteristics

Supply voltage .................................. 11...28 V DC
At UL / CSA approval ................... According to NEC Class 2; 24 V DC (11...28 V DC)
Optional ........................................ 5 V DC ±5%
Current load (unloaded)
11...28 V DC version ................... < 65 mA at 11 V DC, < 45 mA at 28 V DC
5 V DC version ............................. < 80 mA at 5 V DC
*Pulses / revolution .......................... ≥ 2 ... ≤ 8.192
Programming via RS485 .................. PC IBM compatible (TRWinProg)
Version with push-pull
Output level .................................. 11...28 V DC, supply voltage
Output current .............................. ≤ 30 mA
Output frequency.......................... 150 kHz ±15°
Supply voltage.............................. 11...28 V DC
Version with line driver
Output level .................................. 5 V DC, RS422
Output current .............................. ≤ 50 mA
Output frequency.......................... 300 kHz ±15°
Supply voltage.............................. 11...28 V DC, optional 5 V DC
Incremental signals .......................... A+, A–, B+, B–
Zero pulse ......................................... Ref+, Ref–
Programmable parameters.............. - Number of pulses
Inputs ................................................. Preset for set Ref+, Ref–
Switching level ............................. „0" < 2 VDC, „1" = supply voltage
*programmable parameter
Printed in the Federal Republic of Germany
07/13/2006
- Phase position A / B
- Phase position zero pulse(s)
- Zero pulse length
- Number of zero pulses
- Enable/Disable Preset function, Set Ref+, Ref–
TR - ECE - BA - DGB - 0049 - 01
Technical data
© TR-Electronic GmbH 2005, All Rights Reserved