– The appliance surface and the inside of
the container should be cleaned regu-
larly using a damp cloth.
DANGER
Risk due to dust hazardous to health. Al-
ways use disposal clothing and P2 or high-
er breath-safe masks while carrying out
maintenance tasks (such as changing fil-
ters).
Inspection and maintenance work
Have the vacuum cleaner regularly inspect-
ed according to the respective national ac-
cident prevention regulations.
Maintenance work must be carried out by a
specialist at regular intervals in accordance
with the specifications of the manufacturer.
The existing stipulations and safety re-
quirements are to be here observed. Work
on the electrical plant may only be carried
out by qualified electricians.
If you have any more questions, your
KÄRCHER branch will be happy to help.
Maintenance intervals / user
maintenance
No periodic maintenance intervals are
specified for this device. The following
maintenance is to be performed as neces-
sary:
Wash the filter.
Replace the filter.
Replace the filter.
Wash the filter
The filter can be washed out under running
water.
ATTENTION
Risk of damage! Do not use washing
agents or bleach. Only insert the filter into
the appliance when it is completely dry.
Changing/ replacing filter
CAUTION
Health risk from dust escaping. Changing
the filter must be done in a suitable mainte-
nance area. Wear protective gear when
changing the filter.
Dispose of the old filter according to the le-
gal regulations.
1 Lid of filter chamber
2 Filter spreader
3 Washer ring
4 Filter
Remove the hose clamp on the connec-
tion hose. Use a screwdriver.
Open locks.
Remove the lid of the filter chamber.
Pull the new dust bag over the filter
chamber and the inserted filter.
Pull the filter into the dust bag and out of
the device.
Close and dispose of the dust bag.
Thoroughly clean the outside of the de-
vice before inserting a new filter by vac-
uuming it and wiping with a damp cloth.
Check sealing ring for damage.
Insert the new filter in reverse sequence
and take care to ensure that the filter
spreader is aligned correctly in the filter
bag.
– 9
EN
23