Herunterladen Inhalt Inhalt Diese Seite drucken

Kübler CODIX 54U Bedienungsanleitung Seite 24

Anzeigezähler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
4.11 End of programming
The programming routine is
repeated once more. The val-
ues set until now can be
checked and modified.
The programming routine wil be
left and all values set will be
stored as new parameters.
Afterwards the device is ready
for operation.
Electronic tim meter with
2 time ranges
Codix 54U: basic operating mode
1. Description
• 6 digit time meter with Reset function
• Red LED display, character height 14 mm
• Display range 0 ... 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Operation indicator: the decimal point of the
lowest digit blinks while the count is active
• Time meter operating modes:
– Counting while INP B is inactive "GAtE.Lo"
– Counting while INP B is active "GAtE.hi"
– Count Start/Stop with INP B edge (Inb.Inb)
– Count Start with INP A edge, count Stop with
INP B edge (InA.InB)
• Counting ranges: h; min; s; h.min.s
• With AC power supply: sensor supply
voltage 24 V DC ±15 %/100 mA
Page 10 | ENG
2. Inputs
INP A
Start input (depending on the input mode cho-
sen)
INP B
Time meter Start/Stop or gate input (depending
on the input mode chosen)
RESET
Dynamic RESET input. Linked in parallel to the
red RESET key. Resets the counter to zero. Can
be adjusted individually for Counter 1 and
Counter 2.
3. Selection of the displayed value
Pressing the right key allows switching between
the display of time meter 1 and the display of
time meter 2. Press the key briefly to display for
2 seconds the current function ("time1" or
"time2"). If, during this period of time, the right
key is pressed a second time, the device switch-
es to the current function and displays a confir-
mation ("time1" or "time2") for 2 seconds. Then,
the value of the selected function is displayed.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the
factory setting
4.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +U
4.2 Switching on the 30 Hz filter (INP A, INP B)
30 Hz filter off (f
Start/Stop inputs not damped
30 Hz filter on
Start/Stop inputs damped for
use with mechanical switches
B
)
max

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis