Electronic totaliser and time meter
Codix 54U: basic operating mode
1. Description
• 6 digit totaliser and time meter with Reset func-
tion
• Red LED display, character height 14 mm
• Display range 0 ... 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Operation indicator: the decimal point of the
lowest digit blinks while the count is active.
• Time meter operating modes:
– Counting while INP B is inactive "GAtE.Lo"
– Counting while INP B is active "GAtE.hi"
– Count Start/Stop with INP B edge B "Inb.Inb"
• Counting ranges: h; min; s; h.min.s
• With AC power supply: sensor supply
voltage 24 V DC ±15 %/100 mA
2. Inputs
INP A
Dynamic count input for the totaliser.
INP B
Start-/Stop or gate input for time meter
(independent of the input mode)
RESET
Dynamic RESET input. Linked in parallel to the
red RESET key. Sets the counter to zero. Can be
adjusted individually for the totaliser and the time
meter.
3. Selection of the displayed value
Pressing the right key allows switching between
the totaliser display and the time meter display .
Press the key briefly to display for 2 seconds the
current function ("total" or "time"). If, during this
period of time, the right key is pressed a second
time, the device switches to the current function
and displays a confirmation ("total" or "time") for
2 seconds. Then, the value of the selected func-
tion is displayed.
Page 8 | ENG
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the
factory setting
4.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +U
4.2 Switching on the 30 Hz filter (INP A, INP B)
30 Hz filter off (f
Count and start/stop inputs not
damped
30 Hz filter on
Count and start/stop inputs
damped
4.3 Multiplying factor (totaliser)
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
4.4 Dividing factor (totaliser)
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
B
)
max