Note:
the command AAem is generally answered with 'no'
instead of AAm2, AAre can also be used. (Reset after m1 is necessary!)
in the ms command, negative temperatures are represented as ´-0995´ for –99.5 ° or hexadecimal in
2's complement
Setting response time
Setting reset time
Setting analog input
Setting analog output
Setting pilot light
Reading pilot light
External reset
Reading measuring
value
Reading off set points
Setting SetPoint 1 or
SetPoint 2
Setting hysteresis
Analog input
Reading measurement
range
Analog output
Reading measurement
range
Analog input
1.
Setting measure-
2.
ment range
Analog output
1.
Setting measure-
2.
ment range
Reset
Setting Baud rate
Answer time
Setting device address AAgaXX
Reading parameters
Device model / soft-
ware version
Device number
35
AAezX
X = 0 to 6
AAlzX
X = 0 to 8
AAisX
X = 0 (0 - 20 mA)
AAasX
X = 0 (0 - 20 mA)
AAlaX
X = 0 (off)
AAla
Output: D (0 or 1)
AAlx
Simulation of an external reset contact
AAms
Output: DDDDD (in °C/°F with one digit after the dot)
5 decimal digits (88880 = overflow; 80000 = laser on)
AAmsXXX
XXX = 000 to 999 (automatic repetition of the ms com-
mand)
AAsp
Output: XXXXYYYYHHHH
3 x 4 hexdigit for SP1, SP2 (in °C/°F) and hysteresis in
1/10 degrees
AAs1XXXX
XXXX = hexadecimal for temperature in °C/°F within the
AAs2XXXX
AAhyXXXX
XXXX = hexadecimal for temperature *10 in degrees
AAmb
Output: XXXXYYYY
2 x 4 hexdigit for MBA and MBE (°C/°F)
AAme
Output: XXXXYYYY
2 x 4 hexdigit for MBA and MBE (°C/°F)
AAm3XXXXYYYY
XXXXYYYY = 2 x 4 hexdigit for MBA and MBE (°C/°F)
AAm2
AAm2 puts change into effect (auto reset)
AAm1XXXXYYYY
XXXXYYYY = 2 x 4 hexdigit for MBA and MBE (°C/°F)
AAm2
AAm2 puts change into effect (auto reset)
AAre
Auto reset
AAbrX
X = 0 to 5
AAtwXX
Minimum pause time before an answer in bit times
XX = 03 to 99
XX = 00 to 97 (auto reset)
AApa
Output: 11 decimal digits
00......... : always 00
..D........ : response time
...D....... : reset time
....D...... : current output
.....D..... : current input
......D.... : enter unlock
.......DD.. : device address.
.........D. : baud rate
..........0 : always 0
AAve
Output: VVMMJJ
AAsn
Answer: 0DDDD 5-digit decimal
0 = 0.00 sec 1 = 0.01 sec 2 = 0.05 sec 3 = 0.25 sec
4 = 1.00 sec 5 = 3.00 sec 6 = 9.99 sec
(0 ≤ 2 ms)
0 = OFF 1 = 0.01 sec 2 = 0.05 sec 3 = 0.5 sec
4 = 1.00 sec
5 = 5.00 sec
7 = EXTERNAL
8 = AUTO
X = 1 (4 - 20 mA)
X = 1 (4 - 20 mA)
X = 1 (on)
current partial measurement range
0 = 1200 Bd to 5 = 38.4 kBd
VV = 80
MM = Month
JJ = year of the software version
Broadcast
6 = 25.0 sec
(auto reset) +
(comp. ez)
(comp. lz)
(comp. as)
(comp. is)
(status)
(comp. ga)
(comp. br )
+
+
+
+
-
+
-
-
+
+
-
-
-
-
-
+
+
-
-
-
-