6
Technical data
General data and operating conditions
6
Technical data
General data and operating conditions
Communication-relevant data Values
Communication media
Network topology
Number of devices
Cable length / segment
Communication profile
PUO ID number
Drive profile
PROFIBUS participants
Baud rate for cable type A (EN
50170)
Process data words (PCD),
16 bits
DP user data length
External voltage supply
"+"
"-"
Operating conditions
Climatic conditions
Enclosure
Degree of pollution
66
RS 485
without repeater: line / with repeater: line or tree
Standard: 32 (= 1 bus segment) / with repeaters: 125
1200 m
(depending on the baud rate and the cable type used)
PROFIBUS-DP
(DIN 19245 part 1 and part 3)
2133
hex
DRIVECOM profile "Power Transmission 20", can be switched off
PROFIDRIVE version 2, can be switched off
(status machine and PIV interface)
Slave
9.6 kbits/s up to 12 Mbits/s (automatically detected)
1 word ... 12 words
Parameter data channel (4 words) +
process data words (1 .... 12 words)
Values
V = 24 V DC (21.6 V - 0% ... 26.4 V + 0 %)
I = 120 mA
Reference potential for external voltage supply
Values
Storage 1 K3 to IEC/EN 60721-3-1
Transport 2 K3 to IEC/EN 60721-3-2
Operation 3 K3 to IEC/EN 60721-3-3
IP20
2 to IEC/EN 61800-5-1
Deviations from standard
-25 °C ... + 60 °C
0 °C ... + 55 °C
EDKMF2133 DE/EN/FR 4.0