IMPORTANT SAFETY INSTRUCTIONS

WARNING
- To guard against injury, basic safety precautions should be observed, including
the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1.
and all the important notices on the appliance before use. Failure to do so may result in loss
of fish life and/or damage to this appliance.
DANGER
2.
- To avoid possible electric shock, special care should be taken since water is
employed in the use of aquarium equipment. For each of the following situations, do not
attempt repairs yourself; return the appliance to an authorised retailer for service or discard
the appliance.
A. If the appliance shows any sign of abnormal water leakage or if RCD (or GFCI- Ground Fault
Current Interrupter) switches off disconnect the power supply cord from mains and remove
the filter pump from water.
B. Carefully examine the appliance after installation. It should not be plugged if there is water
on parts not intended to be wet.
C. Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or it
is dropped or damaged in any manner. The power cord of this appliance cannot be replaced;
if the cord is damaged, the appliance should be discarded. Never cut the cord.
D. To avoid the possibility of the appliance plug or socket getting wet,
position the appliance to one side of a wall mounted socket to prevent
water from dripping onto the socket or plug. A "drip loop" (see
illustration a) should be arranged by the user for the cord connecting
appliance to a socket. The "drip loop" is that part of the cord below
the level of the socket or the connector if an extension cord is used,
to prevent water travelling along the cord and coming in contact
with the socket. If the plug or socket does get wet, DON'T unplug the
cord. Disconnect the fuse or circuit breaker that supplies power to the
appliance. Then unplug and examine for presence of water in socket.
WARNING
-
3.
This appliance can be used by children aged 8 years and above, persons
with reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a safe way
and understand the hazards involved. Children shall not play with the appliance. cleaning and
user maintenance shall not be made by children without supervision.
4. To avoid injury, do not touch moving parts or hot parts.
CAUTION
5.
– Always unplug or disconnect all appliances in the aquarium from electricity
supply before placing hands in water, before putting on or taking off parts and whilst the
equipment is being installed, maintained or handled. When inserting or removing the filter
pump from the water, always pull out the main electricity plug. Never yank cord to pull plug
from outlet. Grasp the plug and pull to disconnect. Always unplug an appliance from an outlet
when not in use.
6. This appliance is an aquarium filter pump for use in ornamental aquariums. Do not use this
appliance for other than its intended use (i.e.: don't use it with inflammable or drinkable
liquids, in swimming pools or other situations where people are immersed, in garden ponds,
bathrooms, etc.). This appliance is suitable for use in water temperatures up to 35 °C. The
use of attachments not recommended or sold by the appliance manufacturer may cause a
dangerous situation.
7. This filter pump is suitable for INDOOR/HOUSEHOLD use only. Do not install or store the
appliance where it will be exposed to the weather or to temperatures below freezing.
8. Make sure that this appliance is securely installed before operating it and that the electrical
connection is in accordance with the data on the rating label. Do not allow pump to run dry.
The filter pump must be immersed in water completely. This filter pump must never operate
outside of water.
9. If an extension cord is necessary, a cord with proper rating should be used. A cord rated
for less amperes or watts than the appliance rating may overheat. Care should be taken to
arrange the cord so that it will not be tripped over or pulled. The connection should be carried
out by a qualified electrical installer.
SAVE THESE INSTRUCTIONS
10.
ing of this product it is recommended that this manual is thoroughly read and understood.
Failure to do so may result in damage to this product.
a.
For the complete use and understand-
FILTER PREPARATION
1.
Remove filter from bracket (U2, U3, U4) by tilting forward and pulling upwards (a).
2.
Remove the motor from the bottom of the filter by squeezing the blue tabs and pulling down (b).
Gently pull out the impeller fan from the motor (c), rinse the impeller and attached cylindrical
magnet with clean water (d). Place back into the motor and re-attach the motor to the filter.
3.
Open the flip top cover and remove the filter media.
4.
Rinse the foam pad/s and cartridges in clean water
5.
Remove and open the central media cartridge (Fluval U2/3/4 only) and empty the Biomax
biological media from its bag into the cartridge, rinsing under a running tap.
6.
Attach the suction cups to the filter body (Fluval U1) (e) or filter bracket (Fluval U2/3/4) (f)
7.
Insert the directional nozzle/s to the water outlet/s (g), ensuring the nozzle with the venturi vent is
installed on the top nozzle (Fluval U2/3/4 only)
8.
If using the venturi aeration system, place it into the top of the nozzle (g).
a.
b.
c.
d.
INSTALLING THE FLUVAL CLEAN & CLEAR WATER CLEANSING
CARTRIDGE
(AVAILABLE SEPARATELY)
The Fluval Clean & Clear cartridge has been proven to reduce phosphate and nitrate levels for clearer,
safer water and longer intervals between water changes. Replace every month for optimal effectiveness.
1. Fluval U1: Remove the central foam cut-out section and retain for future use if required. Remove the
Clean & Clear cartridge from its bag and insert fully into the foam, with the easy removal tab on top
(a-b).
The use of media other than that designed specifically for use with Fluval U filters may
obstruct water flow or damage the impeller – proceed with caution and at your own risk.
2. Fluval U2/3/4: Remove and open the central media cartridge (c) and position the Biomax biological
media into the top half of the cartridge. Insert the Clean & Clear cartridge/s into the lower half of
the cartridge (d) (one cartridge in Fluval U2, two cartridges in Fluval U3/4).
a.
b.

INSTALLING THE FILTER

WARNING:
Disconnect the electrical plug of all appliances inside the aquarium before putting hands
into the water.
1. Fluval U2/3/4 only: Slide the filter into its bracket and clip into place, ensuring the power cable is
correctly routed through the cable clip.
2. Position the filter so the top outlet is at least 1cm below the water surface, with the venturi above
the water surface (if used).
3. Firmly push the suction cups onto the aquarium glass.
4. With dry hands, plug the filter in, ensuring a drip loop is built into the cable.

FILTER ADJUSTMENT

1. Turn the blue water control paddle located under the lid to adjust flow rate and
direction.
2. Fluval U2/3/4: Water flow can be directed as follows:
A. Top output – for maximum circulation and oxygenation
B. Spray bar – a gentle flow ideal for planted aquariums
C. Bottom output – for deep water agitation and maximum circulation
3. Turn the blue dial on the venturi device (if used) to adjust the volume of air
produced (NOTE: Air from the Venturi will only be purged from the top output)
e.
f.