Herunterladen Inhalt Inhalt Diese Seite drucken

Getting To Know The Technical Data - Meister AS108VM Originalbetriebsanleitung

Akku-bohrschrauber
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5401030-Akku-Bohrs-man 18.02.14 09:30 Seite 48
Figure 4-8 (left type plate):
Text
Nr.
Bj.
SN
10.8 V
Li-Ion
n
I:
0
n
II:
0
Meister...

Getting to know the technical data

Physical data
Cordless drill-screwdriver
Dimensions of the
cordless drill-screwdriver
with rechargeable battery
approximately
Weight with
rechargeable
battery
Tool receiving
socket
Chuck maximum
diameter
Idle revolutions
First gear/
second gear
Torque
maximum
Electrical data
Cordless drill-screwdriver
Operational voltage
Battery type
Battery voltage
Battery capacity
48
Meaning
Item number
Year of construction
Serial number
Operational voltage
Lithium-ion battery
Idle revolutions in first
gear: 0–350 rpm
Idle revolutions in
second gear:
0–1.000 rpm
Manufacturer
specification
200 x 215 x 55 mm
1.080 g
10 mm
0–350/min,
0–1.000/min
15 Nm
10.8 V – ...
3 x lithium-ion
3 x 3.7 V – ...
1.300 mAh
Ergonomic data
Cordless drill-screwdriver
Sound level
Sound power level
Vibrations when drilling
Vibrations when screwing 0,34 m/s
Measuring inaccuracy K: 1,5 m/s
The measured vibration
values were determined in
accordance with EN 60745.
The specified vibration emission value
was measured in accordance with a
normed test procedure and can be used
in order to compare one electrical tool
with another.
The specified vibration emission value
can also be used for an introductory
evaluation of the influence.
The vibration emission value may
fluctuate from the specified value during
use of the electrical tool. These
fluctuations will depend on the way in
which the tool is used.
Safety measures must be taken in order
to protect the operator. As a result, the
evaluation of the influence must be
made whilst taking account of the actual
conditions of use. (All parts of the
operating cycle must be taken into
account for this purpose. This also
includes times in which the tool is
switched off and times in which it is
switched on, but is running without
load.)
Electrical data of plug power supply
Type
Operational voltage
Network frequency
L
= 73 dB(A)
pA
K
= 3 dB
pA
L
= 84 dB(A)
wA
K
= 3 dB
wA
2
1,49 m/s
2
2
XR-DC120400A
220...240 V
50/60 Hz

Werbung

Inhaltsverzeichnis
loading