Herunterladen Inhalt Inhalt Diese Seite drucken

Reading The Dew Point; History Record For The Past 24 Hours; Max/Min Weather Data; Technical Data - Bresser 5-in-1 Comfort Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 5-in-1 Comfort:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

27 Reading the dew point

Press the INDEX button several times until DEW POINT is displayed.
Note:
The dew point is the temperature below which the water vapor in air at constant barometric pressure
condenses into liquid water at the same rate at which it evaporates. The condensed water is called
dew when it forms on a solid surface. The dewpoint temperature is calculated from the indoor temper-
ature and humidity measured at the main unit.

28 History record for the past 24 hours

The base station automatically records and displays data of the past 24 hours.
1. Press the HISTORY button to check history records of the last hour.
2. Press the HISTORY button several times to display the history records of the hours 2,3,4,5 ......

29 MAX/MIN Weather data

The base station preserves the MAX/MIN weather data records until the next manual reset. To retrieve
the data:
1. Press MAX/MIN button several times to display the stored values one after another.
2. Display order: Outdoor max temperature > Outdoor min temperature > Outdoor max humidity >
Outdoor min humidity > Indoor max temperature > Indoor min temperature > Indoor max humidity
> Indoor min humidity > Outdoor max wind chill > Outdoor min wind chill > Outdoor max heat index
> Outdoor min heat index > max dew point > min dew point > max pressure > min pressure > max
average > max gust > max rainfall
3. Press MAX/MIN button for approx. 2 seconds to delete all saved values.

30 Technical data

Power supply
Backup battery
Temperature measuring range
Dimensions
Weight
Table 1: Base station
Batteries
RF Übertragungsfrequenz
RF Übertragungsreichweite
Maximum radio-frequency power
Temperature measuring range
Barometer measuring range
Humidity measuring range
Humidity resolution
Rainfall measuring range
Wind speed measuring range
Dimensions
Weight
Table 2: Multisensor
38 / 44
DC 4.5V 300 mA mains plug
Type: YJ02-G0450300D
3x AAA, 1.5V
-5°C to 50°C
202 x 138 x 38 mm
530 g
3x AA, 1.5V
868 Mhz
150 m
< 25 mW
-40°C to 80°C (-40°F to 176°F)
540 to 1100hPa
20% to 90% RH
1% HR
0 to 9999 mm (0 to 393.7 inch)
0 to 112 mph, 50 m/s, 180 km/h, 97 knots
343.5 x 393.5 x 136 mm
673 g