Herunterladen Inhalt Inhalt Diese Seite drucken

Display Indications And Symbols - VOLTCRAFT VC-585 Bedienungsanleitung

Digitales zangen-multimeter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Dial switch (13)
The individual measuring functions are selected via a rotary control. The automatic
range selection "AUTO" is active for some measuring functions. The appropriate meas-
urement range is set individually for each application.
If the multimeter switch is set to "OFF", the meter is switched off. Always turn the meter
off when it is not in use.
The figure shows the measuring function layout.

8. Display Indications and Symbols

The following symbols and information are present at the device or in the display:
AUTO
Automatic measurement range selection is active
Automatic deactivation is active
OFF
Switch position "off" or function deactivated
NCV
Contact-free alternating voltage recognition (only V-AC)
True RMS
True root mean square
Data-Hold function is active
HOLD
Call/deactivate data hold function
MAX-MIN
Max-Min function is active
MAX
Display of the maximum value of the current measuring series
MIN
Display of the minimum value of the current measuring series
REL
Setting relative value measurement and reference values (not possible at continuity test, diode test,
frequency and NCV)
Δ
Delta symbol of relative value measurement (= reference value display)
OL
Overflow display, the measuring area was exceeded
Battery change symbol. Replace the batteries as soon as possible to avoid measuring errors!
Symbol for the battery data used
Symbol for the diode test
Symbol for the acoustic continuity tester
AC
Symbol for alternating current
DC
Symbol for direct current
V, mV
Volt (unit of electric voltage), Milli-Volt (exp.–3)
A
Ampere (unit of electric current)
Hz, kHz, MHz Hertz (unit of electrical frequency), Kilo hertz (exp.3), Megahertz (exp.6)
%
Symbol for the pulse ratio of the positive half-wave
35