The switching element should not be removed from its enclosure for
connection. If the switching element is removed, use for example a
screwdriver to press down the metal plunger while reinserting it.
Mounting the position switch using two screws, min. M 5 x 40;
tightening torque = 1.2 Nm
When explosion-protected electrical equipment is exposed to the weather, it
is advisable to provide a protective cover or wall.
8
Transport and Storage
Transport and storage are only permitted in the original packing.
9
Installation
Mains Connection
The conductors must be carefully connected.
The conductor insulation must reach to the terminal. The conductor itself must not be
damaged (nicked) when removing the insulation.
Ensure that the maximum permissible conductor temperatures are not exceeded by
suitable selection of cables and means of running them.
Please also refer to the terminal details in the technical data.
131955 / 8070603300
S-BA-8070/1-02-en-29/10/2008
11443E00
Transport and Storage
11449E00
Position Switch
8070/1
13