NOTE:
• The DC receptacle can be used while the AC power is in use.
If you use both at the same time, do not exceed the maximum AC
power.
Maximum AC power:
EM25: 2.19 kVA
EM30: 2.48 kVA
• Most appliance motors require more than their rated wattage for
startup.
• Make sure the electrical rating of the tool or appliance does not
exceed that of the generator. Never exceed the maximum power
rating of the generator. Power levels between rated and maximum
may be used for no more than 30 minutes.
• Limit operation requiring maximum power to 30 minutes.
Maximum power is:
EM25: 2.5 kVA
EM30: 3.0 kVA
• For continuous operation, do not exceed the rated power.
Rated power is:
EM25: 2.3 kVA
EM30: 2.6 kVA
• In either case, the total power requirements (VA) of all appliances
connected must be considered.