Description
768
Power limiter changed
during grid power feed op-
eration
772
Memory on memory PC
board cannot be accessed;
inverter infeed is deactivat-
ed for safety reasons
773
Memory on memory PC
board not initialized; invert-
er infeed is deactivated for
safety reasons
775
Incorrect programming of
power module
782* - 783*
Error during update
784* - 787*
1000* -
Service Messages
1001*
1201* -
Service Messages
1210*
* ... Code only appears during event logging and in the error counter
Operation in
When operating the inverter in extremely dusty environments:
dusty environ-
when necessary, clean the cooling elements and fan on the back of the inverter and the
ments
supply air openings in the mounting bracket using clean compressed air.
Behavior
1. Integrated memory PC
board is connected or switched
off during grid power feed op-
eration
1. SSP not connected
1. Memory not programmed or
memory lost
2. Faulty Recerbo
1. Power module or filter PC
board not programmed
1. Occurs once
2. Recerbo faulty
1. Occurs once
2. Recerbo faulty
Harmless if no errors have oc-
curred during grid power feed
operation; just give information
about the status of the internal
processor
Harmless if no errors have oc-
curred during grid power feed
operation; just give information
about the status of the internal
processor
Remedy
1. Automatically corrected (sta-
tus code must be confirmed)
1. Check SSP
1. Reload setup
2. Replace Recerbo
1. See device -> info menu:
Search for missing version info
and replace faulty PC board
1. Automatically corrected
2. Replace Recerbo
1. Automatically corrected
2. Replace Recerbo