Herunterladen Diese Seite drucken

Parkside 420314 2207 Originalbetriebsanleitung Seite 24

Klarwasser-tauchpumpe

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
GB
MT
Check that the pump is resting on the
pit base
Check that the pressure line has been
attached properly
Check the proper status of the electrical
plug socket and make sure that the plug
socket is suffi ciently fused (at least 6 A).
Insert the pump plug into the plug socket
and the pump is ready for operation.
Make sure that moisture or water never
come in contact with the mains connec-
tion.There is a risk of electrocution.
The minimum water level on initial
start-up must be 50 mm.
Operation
Mains connection
The submersible water pump acquired by
you is already provided with an grounded
plug. The equipment is designed for con-
nection to an earthed wall socket with a
residual current operated device (RCD
switch) at 230 V ~ 50 Hz.
Only start to operate the device
after all the above conditions have
been observed.
Switching on and off
1. Insert the plug in the socket. The pump
starts working immediately.
The pump immediately starts running
when the swimming switch is in the
correct position (see „Automatic opera-
tion" and „Manual operation").
2. To switch off, withdraw the plug from
the socket. The pump stops.
If the water level is too low, the
fl oat switch will automatically
switch off the pump.
24
Supervise the appliance while it is
in operation in order to be immedi-
ately aware if the automatic cut-out
operates or the pump runs dry, to
limit any damage to a minimum.
Automatic mode
In automatic mode, the fl oat switch (5) au-
tomatically switches the pump on or off.
In the case of stationary installation,
check regularly (no less then once
every three months) that the fl oat
switch (5) is working.
The On/Off switch point of the fl oat switch
(5) is infi nitely variable:
You can vary the switch-on and switch-off
point by:
- adjust the position of the fl oat switch
height adjustment (6) on the fl oat switch
guide (8).
- varying the length of the fl oat switch ca-
ble (7). Push/pull the cable (7) through
the eye on the retaining clip (6) for this.
Check the
fl oat switch (5).
-
It must be positioned so that it can lift
and lower freely. The switching point
heights "On" and "Off" must be easy to
reach.
Check this by placing the pump into a
vessel fi lled with water and lift the fl oat
switch (5) carefully by hand and then
lower it again. In this case, you can see
whether the pump switches on and off.
-
Make sure that the distance between
the fl oat switch (5) and the fl oat switch
height adjustment (6) is not too short. If
the distance is too short, the device may
not work properly.

Werbung

loading

Diese Anleitung auch für:

Ptpk 400 b1