ELECTRICAL WIRING
The electrical wiring connection between the outdoor unit and the indoor unit is shown in figure below:
Power Source
220-240V~ 50Hz
ELB
FUSE
SWITCH
power source cable
9.3 ELECTRICAL WIRING CONNECTION
FOR OUTDOOR UNITS
The electrical wiring connection for the outdoor unit is shown
in the figure below:
External view:
Outdoor unit
TB2
TB1
transmission cable
Shielded twisted pair cable 0.75mm
This cable dose not need any polarity.
Do not apply an excessively high voltage to this cable (Rated
Voltage:5V).
Wiring cover
Power source cable
Transmission cable
Power Source
220-240V~ 50Hz
Indoor unit
ELB
TB1
FUSE
SWITCH
power source cable
x 2.
2
?
N O T E
Knock out the holes of the wiring cover before
wiring connection.
hole for
transmission
cable
!
C A U T I O N
The wiring cover must be installed back after
the wiring connection work, and make sure it is firmly
fixed. Otherwise, the water or dust may enter, and
cause an electric shock.
18
TB4
Wiring
cover
hole for
power source cable