Index
Sub-
(hex)
index
(hex)
0x0304
0x00
0x0305
0x00
8.2.3.8.1 Measurement Data Information
Lower Value: This value indicates the start of the measuring range (lowest possible mea
sured value). The lowest possible measured value of compression force transducers is
the end of the measuring range as a negative number.
Upper Value: This value indicates the end of the measuring range (highest possible mea
sured value).
Unit code: The IO-Link standard defines various units. Here you will find the code of the
unit being used (usually Newton) as per the IO-Link standard.
Index
Sub
(hex)
index
(hex)
0x4080 0x01
0x4080 0x02
0x4080 0x03
50
Authoriza
Data type
tion
ReadOnly
Float32T
ReadOnly
Float32T
Authoriza
Data type
tion
ReadOnly
Float32T
ReadOnly
Float32T
ReadOnly
UIntegerT 2
Data
Name
size
(bytes)
4
Compressive
Force Max
4
Tensile Force
Max
Data
Name
size
(bytes)
4
MDC Descriptor
– Lower Value
4
MDC Descriptor
– Upper Value
MDC Descriptor
– Unit Code
Description
Highest
compressive
force ever
measured
Highest
tensile force
ever
measured
Description
Lower limit
value of the
measurement
data range
Upper limit
value of the
measurement
data range
Current physi
cal unit of the
measurement
data in the
process data;
see IO-Link unit
codes
ELECTRICAL CONNECTION