10. Supplement to ex-protection implementation

EU conformity declaration in the sense of the EU directive 94/9/EG (ATEX)
We, the HOMA Pumpenfabrik GmbH, Industriestrasse 1, D-53819 Neunkirchen-Seelscheid hereby declare that
the submersible motor model series
AM
and the submersible motor pump series
H
MX
due to their design and construction as well as the manner in which they have been put into use, conform to the
present fundamental safety and health requirements of the EU Directive 94/9/EG for their intended use in
potentially explosive areas. This declaration loses its validity, in the case of a change of the explosion-protected,
submersible motors, pumps and agitators not approved by us.
Designation:
Submersible motors and pumps with the abbreviations of the abovementioned series in the article
designations characteristics for the electrical and mechanical parts:
For pumps adapted with the following
submersible motors
(C)AM 120; (C)AM 122; (C)AM 136;
(C)AM 173;
CAM 206; AM 204; AM 243; AM 303
AM 376; AM 421; AM 500
Applied conformity evaluation process:
Module: quality assurance production DEKRA .. ATEX Q...
Named position for the exhibition of EU type examination certificate:
DEKRA Certification B.V. NL (label 0344)
DEKRA or KEMA . . ATEX . . . .
Applied directives:
94/9/EG
98/37/EG
Applied harmonized standards, technical specifications
EN 60079-0:2012
EN 60079-1:2007
EN 60079-7:2007
EN 60079-11:2012
EN 1127-1:2007
EN 13463-1:2009
EN 13463-5:2011
Vassilios Petridis
Manager development and production
Responsible for compilation of technical documentation
HOMA Pumpenfabrik GmbH
Industriestr. 1
53819 Neunkirchen- Seelscheid (Germany)
CAM
CH
CTP
V
VX
Marking
II 2 G Ex c d IIB T4 (T3)
II 2 G Ex c d e IIB T4(T3)
Devices for intended use in potentially explosive atmospheres
EU machine directive
General requirements electrical equipment for potentially explosive
atmospheres
Flameproof enclosures "d" for electrical equipment for potentially explosive
atmospheres
Equipment protection by increased safety "e" for potentially explosive
atmospheres
Equipment protection by intrinsic safety "i" for potentially explosive
atmospheres
Potentially explosive atmospheres: explosion prevention and protection - Part 1:
Basic concepts and methodology
Non-electrical equipment for use in potentially explosive atmospheres - Part 1:
Basic method and requirements
Protection by construction safety "c"
TP
GRP
K
KX
Marking for model with
Integrated seals sensor
II 2 G Ex c d ib IIB T4 (T3)
II 2 G Ex c d e ib IIB T4 (T3)
According to Appendix VIII of the 94/9/EG
Author: Stein
Date: 11.18.2009
62
Index: 3
Seq. No: EX 01