10. MAINTENANCE
WARNING: these use and maintenance instructions are intended
only for
a staff qualified for the installation and maintenance of
electrical and gas equipment. Maintenance by other persons may cause
damage to the equipment, persons, animals or things.
In the majority of cases it is necessary to remove the fixed guards in
order to carry out repairs and checks. This also renders the voltage cables
accessible.
Before carrying out any maintenance operations check that the
equipment's feed cable plug is disconnected from the switchboard. Put
the plug in a place where the maintenance operator can easily ascertain,
during all of the work done with the guards removed, that it has been
disconnected.
10.1. ERROR WARNING
Electronic controls is able to identify some malfunctions, for details see
paragraphs 7-6.
10.2. SAFETY THERMOSTAT
The safety thermostat intervenes when the temperature in the chamber
goes above 500°C and de-activates the resisters. The safety thermostat is
located on the outside of the switchboard under the conveyor belt.
To correct the error unplug the feed panel and wait for the chamber to cool
down.
Unscrew the cap of the safety thermostat reset button and press the button.
Resetting is not possible until the temperature in the chamber has fallen below
500°C.
Since the safety thermostat only intervenes where there are serious
malfunctions, carefully check the oven's working and repair if necessary before
starting up the oven again.
28
Synthesis 05/40V
MAINTENANCE