9. Specifications
9.2 Models TLS-C/TLS-H
Basic information
Electrical connection
EN
Cable gland
Process connection
Mounting thread
downwards
Mounting flange
Clamp
Food-compliant connection
Material
Connection housing
Wetted parts
Ambient temperature
Supply voltage
Process temperature
Density of the medium
Max. operating pressure
Switching output
Power consumption
Max. switching power
(relay output)
Ingress protection per
IEC/EN 60529
M12 connector
4-pin coupler connector
per DIN EN 175301-803
→ For further specifications, see WIKA data sheet LM 30.10.
34
Coupler connector
M20 x 1.5
½" NPT
¾" NPT
G ¾" ... 2"
¾" ... 2" NPT
DN 25 ... DN 100 per DIN EN 1092-1
1" ... 4" per ASME B16.5
1" ... 4" per ASME BPE
DN 20 ... DN 100 per DIN 11851
DRD651
Stainless steel 1.4404 (316L)
Stainless steel 1.4404 (316L)
Stainless steel 1.4404, 1.4435 (316L), electropolished
Hastelloy C-276
Hastelloy C-276, electropolished
-40 ... +60 °C [-40 ... +140 °F]
DC 10 ... 30 V
-40 ... +100 °C [-40 ... 212 °F]
-40 ... +150 °C [-40 ... +302 °F]
≥ 0.5 ... 2.5 g/cm³
-1 ... +64 bar [-14.5 ... +928 psi]
PNP relay output
PNP transistor output
< 1 W
DC 30 V / 5 A
IP66/68
IP66/68
IP65
WIKA operating instructions, models TLS-S, TLS-C, TLS-H
4-pin per DIN EN 175301-803,
M16 x 1.5
M12 coupler connector, 4-pin