TechnicalData
6.4.2. Pneumatic data
Control medium: Quality classes in accordance with DIN ISO 8573-1
Dust content:
Class 5:
Water content: Class 3:
Oil content:
Class 5:
Temperature range
of compressed air:
Pressure range
Air flow rate I
/min
N
(for aeration and deaeration) (Q
Connections
6.4.3. Hydraulic data
Medium:
Max. operating pressure:
Ambient temperature:
Water connections
on the block:
All manuals and user guides at all-guides.com
Type 8821
max. particle size 40 μm,
max. particle density 10 mg/m
max. pressure dew point -20°C or
min. 10°C below the lowest
operating temperature
max. 25 mg/m
3
-10 to +50°C
3.0 to 9.5 bar
value according to definition for
Nn
pressure drop from 7 to 6 bar absolute)
Plug-in hose connector
Ø 6 mm / 1/4"
Water, cooling water
9.5 bar
+5 to +55°C
See "Fig. 7", page 17
6.4.4. Electrical data
Valve
Connection:
3
Power supply:
Sensor:
Connection:
Power supply:
Measuring precision:
Output:
DIN 43650 form B with M12 adapter
24 V DC
M12 connector
12 - 30 V DC
+/- 1% of the final value, 3% of the mea-
sured value at a flow rate of 0.3 to 10 m/s
1 impulse /revolution, transistor NPN
700 mA