Herunterladen Diese Seite drucken

Parkside PRP 400 B1 Originalbetriebsanleitung Seite 25

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6
Maintenance/
Cleaning/ Storage
Clean and maintain your equipment regu-
larly. This will guarantee its performance
and long durability.
Ask our service centre to car-
ry out any work that is not
described in these instruc-
tions. Use only original parts.
There is a risk of injury!
Pull out the power plug before
every maintenance operation. There
is a risk of electrocution or of injury
from moving parts.
General cleaning instructions
• Clean the pump with clean water after
each use.
• Remove any fl uff and fi brous particles
that may have become trapped on and
under the pump housing (3) with a wa-
ter jet.
• Clean the fl oat switch (1) and the suc-
tion foot (4) of deposits with clear wa-
ter.
Cleaning the fi lter
The pump has a removable fi lter in the
suction foot that protects it from contamina-
tion. Depending on the degree of contami-
nation of the water, it should be checked
occasionally and cleaned if necessary:
1. Unplug the mains plug.
2. Turn the fi lter cover ( 22 ) a ¼ turn clock-
wise.
3. Remove the fi lter cover ( 22 ).
4. Clean the fi lter ( 23 ) under running wa-
ter.
5. Install the fi lter ( 23 ) and fi lter cover ( 22 )
in reverse order.
The pump must not be operated
with the fi lter ( 23 ).
Flushing the pump
After pumping heavily polluted water, the
pump must be fl ushed to prevent deposits
in the pump.
• Pump lukewarm water (max. 35 °C)
until the pumped water is clear.
Storage
• Clean the pump before storage.
• Store the appliance in a dry, frost-free
place, and where children cannot gain
access to it.
• When the pump is not to be used for
a longer period, it must be thoroughly
cleaned after its last use, and before it
is next used. Otherwise there may be
problems in starting the pump, caused
by deposits and residues.
Space-saving storage
1. Dismantle the fl exible pipe (17) and the
upper aluminium pipe (19).
2 Clip the fl exible pipe (17) and the up-
per aluminium pipe (19) right and left
into the pipe holder (12).
Keep the sealing rings ( 13/14 ) in a
safe place.
All other measures, particularly
opening the pump must be carried
out by a qualifi ed electrician. Al-
ways contact the Service Centre if
repairs are needed.
GB
MT
25

Werbung

loading