Connecting the refrigerator
Item
Description
4
R232 interface
5
CI bus data (pin 1)
6
CI bus grounding
7
Light
8
D+
9
DC connection cable (electronics)
10
S+ (optional)
11
Relay 30 A
12
DC connection cable (heating element)
13
DC heating cartridge
14
NTC 2 (optional)
15
NTC 1 sensor (air)
16
Gas valve
17
AC connection cable
18
AC heating cartridge
19
Ignition and monitoring electrode
AC power
➤ Connect the refrigerator with the mains plug to an AC socket.
DC power
Please note the following cable sizes:
– RM(S)8xx6: <6 m (interior): 4mm
– RMD8xx6: <6 m (interior): 6 mm
– Connections D+ and S+: 1 mm
– Cable fed via draw bar (campers only): 2,5 mm
➤ The power supply line to the heating element (fig. o 12, page 8) must be
protected by a fuse:
– RM(S)8xx6: 12 A fuse
– RMD85x6: 20 A fuse
24
>6 m (interior): 6 mm
>6 m (interior): 10 mm