13. CLEAR THE LATHE BED OF ALL OBJECTS (tools, scraps of wood, etc.) before turning the
machine "ON". FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS INJURY.
14. EXAMINE THE SET-UP CAREFULLY before turning the machine "ON".
15. STAND CLEAR, AND KEEP ALL OBSERVERS AND PASSERSBY clear of rotating path of
workpiece to avoid injury from flying debris.
16. USE THE LOWEST SPEED when starting a new workpiece. NEVER EXCEED recommended
speeds.
17. NEVER ADJUST THE TOOL REST while the workpiece is turning.
18. NEVER LOOSEN THE TAILSTOCK SPINDLE or the tailstock while workpiece is turning.
19. MOVE THE CUTTING TOOL INTO THE WORK-PIECE SLOWLY, and cut small amounts when
roughing.
20. REMOVE THE TOOL REST before sanding or polishing.
21. NEVER PERFORM LAYOUT, assembly, or set-up work on the table/work area when the
machine is running.
22. TURN THE MACHINE "OFF" AND DISCONNECT THE MACHINE from the power source be-
fore installing or removing accessories, before adjusting or changing set-ups, or when making
repairs.
23. TURN THE MACHINE "OFF", disconnect the machine from the power source, and clean the
table/work area before leaving the machine. LOCK THE SWITCH IN THE "OFF" POSITION to
prevent unauthorized use.
24. ADDITIONAL INFORMATION regarding the safe and proper operation of power tools.

2 GROUNDING INSTRUCTIONS

All grounded, cord-connected machines: In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to reduce the risk of electric shock. This
machine is equipped with an electric cord having an equipment-grounding conductor and a
grounding plug. The plug must be plugged into a matching outlet that is properly installed and
grounded in accordance with all local codes and ordinances. Do not modify the plug provided - if
it will not fit the outlet, have the proper outlet installed by a qualified electrician. Improper con-
nection of the equipment-grounding conductor can result in risk of electric shock. The conductor
with insulation having an outer surface that is green with or without yellow stripes is the equip-
ment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do
not connect the equipment-grounding conductor to a live terminal.
Check with a qualified electrician or service personnel if the grounding instructions are not com-
pletely understood, or if in doubt as to whether the machine is properly grounded.