TROUBLESHOOTING

ECTIVE SC Pro charge controllers automatically detect a variety of possible
errors� In this case, the error LED lights up (see p� 22) and an error code
appears on the LCD display� In the following overview you will find the
meaning of each error code so that you can correct the fault
Error code
Error description and troubleshooting
E00
There is no error�
Deep discharge of the battery:
E01
Battery voltage is too low� DC consumer is not supplied with power
until the battery is sufficiently charged again�
Battery overvoltage:
E02
Battery voltage is above the limit of the charge controller� Please
check if the battery is compatible with the charge controller�
Short circuit on the DC load:
E04
Remedy the short circuit�
Overload of the DC load:
E05
Reduce the load or use a charge controller with a higher output
current�
Overheating of the charge controller:
E06
The temperature is above the operating range of the charge
controller� Ensure that the charge controller can cool down�
Battery overheating:
E07
The temperature measured by the external temperature sensor is
too high� Ensure that the battery can cool down�
Solar overvoltage:
The voltage of the solar modules is higher than the nominal voltage
E10
of the charge controller� Reduce the voltage of the connected solar
modules�
Reverse polarity of the solar module:
The solar modules are connected incorrectly� Reconnect them and
E13
make sure that the polarity is correct� (Error message is not displayed
on ECTIVE SC 60 Pro! The device is nevertheless protected)
Reverse polarity of the battery:
E14
The battery is connected incorrectly� Reconnect it and make sure
that the polarity is correct�