DC load settings:
On the „DC Load: Mode" page of the display mode, you can switch to the DC
Load settings by pressing and holding the button
Select mode:
Use the and buttons
Confirm mode:
Press and hold the button
Discard changes:
Press the button
, to return to the display mode without saving changes�
Mode
Description
Automatic control according to daylight:
0
DC power is turned on when no daylight can be detected�
Automatic control according to daylight with timer:
The DC load is switched on when no daylight can be measured� It
1 - 14
is automatically switched off again after [1-14] hours� Enter the
number of hours for the timer here�
Manual mode:
15
The DC consumer is switched on or off when the button
pressed in the display mode
Test mode:
16
The DC consumer is switched on and off in rapid succession�
Always On:
17
The DC load remains on continuously�
and
to switch between the different modes�
to confirm the selected mode�
�
is
SC Pro | LCD Display