20 seconds after the last input, the display illumination turns off automatically�
If the charge controller detects an error, the „Error code" page is automatically
displayed� Use the table on p� 28 to identify and correct the error�
From the display mode, you can switch to the setting mode by pressing and
holding the key
(note: this does not work on the „DC load: mode" page)�
The Settings Mode
In the settings mode, you can change individual settings of the solar charge
controller� You can tell that you are in display mode by the icon
right corner of the display
Set battery type:
In the settings mode, you can set the battery type� Use the
to switch between the following battery technologies
FLD: „Flooded Battery" - wet battery
■
SEL: „Sealed/AGM Battery"
■
GEL: Gel battery
■
■ LI:
Lithium Battery
■ USE:
Advanced User Mode, see below
Press and hold the button
When the charge controller is set to „FLD", „SEL" or „GEL" mode, the optimum
parameters for the respective battery technology are automatically set�
In „LI" mode, some parameters can be adjusted manually to optimize opera-
tion for the connected lithium battery�
In „USE" mode, almost all parameters can be adjusted manually�
to confirm the selected battery technology