EE05
d6-TH3 exhaust temperature protection
EE06
Controller fault
EE07
Compressor protection
EE08
Communication error between the
controller and the power board
EE09
Communication error between the
controller and the control board.
EE10
High voltage protection
EE11
Faulty motherboard for IPM module
EE12
The power supply is too low
EE13
Electrical protection
EE14
Abnormal IPM module operating
temperature
EE15
IPM module high temperature protection
Insufficient refrigerant.
Insufficient water flow rate.
Clogged filter or electronic valve.
d6-TH3 sensor fault.
The connection is faulty.
The controller is faulty.
The connection is faulty.
Accumulation of liquid and gas.
Faulty compressor or printed circuit
board.
Abnormal water flow rate.
Fluctuating power supply.
The connection is faulty.
The controller is faulty.
The connection is faulty.
The controller is faulty.
Voltage too high.
Faulty power board.
The data is incorrect.
The connection is faulty.
Accumulation of liquid and gas.
Faulty compressor or printed circuit
board.
The power supply is incorrect.
The power board is faulty.
The data is incorrect.
The water flow rate is insufficient.
The voltage is unstable.
PFC failure.
The power supply is incorrect.
The fan motor is defective or the
propellers are broken.
The power supply is incorrect.
The fan motor is defective or the
propellers are broken.
Check for the presence of gas
leaks and add refrigerant.
Check the by-pass valve.
Check refrigerant levels.
Check the d6-TH3 sensor.
Check the connection.
Replace the cable.
Replace the controller.
Check the connection.
Check the power supply voltages
Check the phases.
Check the water flow rate.
Check the electrical grid.
Check the connection.
Replace the cable.
Replace the controller.
Check the connection.
Replace the cable.
Replace the controller.
Check the voltage.
Replace the power board and/or
control board.
Programming error, disconnect
the power supply and start after 3
minutes.
Check the connection.
Check the power supply voltages
Check the phases.
Check the power supply voltage.
Replace the board.
Check the compressor.
Check the water flow rate.
Check the power supply voltages.
Check the power board.
Check the fan speed
Check the propellers.
Check the printed circuit board.
Check the fan speed
Check the propellers.
EN