Instructions for use for the user
The vaporizer (humidity function 6) can only be started when the sauna
heater (temperature function 5) is switched on. The maximum humidity
that can be set depends on the temperature of the sauna. The higher the
sauna temperature, the lower the maximum humidity level which can be
set (see characteristic curve on page 13).
Exception: Vaporizer single mode is activated (see "Activating vaporizer
single mode (Pro D3 / Pro D3i only)" on page 32). The vaporizer
can also be operated here without the sauna heater, with the maximum
humidity depending on the current sauna cabin temperature.
If the sauna control unit is used without a humidity/temperature sensor
(FTS2), cyclic mode is activated. If the sauna cabin temperature is less
than 30° C, the vaporizer is activated continuously for 10 minutes. This
ensures that the water in the tank reaches a basic temperature level.
Cycle mode then starts.
10.8. Switching off combi mode (Pro D3 / Pro D3i only)
● Select the temperature symbol 5 by pressing the mode button D. Then
briefly press the On/Off button A.
► The sauna heater and the vaporizer are switched off.
► The display 1 shows "oFF"