AD DRYER
19.4. Setting the drying mode during commissioning
It is recommended to set the air-drying mode during commissioning. These settings are changed
in the service menu in the SERVICE SETUP section. Access to the service menu is protected by a
code.
The drying mode is set based on the expected pressure range in which the device will operate and
the version of the compressor (with or without a cabinet).
compressor without a cabinet t
compressor without a cabinet t
compressor without a cabinet t
compressor in cabinet - set to ENHANCED mode
t
- ambient temperature
O
20. MAIN SCREENS
The home screen opens once the user interface language and drying mode are set. There are 4
main screens accessed from the home screen.
The arrows at the bottom of the screen are used to navigate between the individual screens.
05/2022
< 25 ̊ C - set to ECONOMY mode
O
= 25 ̊ C - 30 ̊ C - set to STANDARD mode
O
> 30 ̊ C - set to ENHANCED mode
O
57
Reset and adjustment of service
intervals, reviewing service and alarm
messages
Adjustment of the dryer pressure
version
Adjustment of the dryer mode
NP-DK50 2V 50, 2x2V 110-AD-A-2_05-2022