Check to ensure the display connector is removed prior to removing the front
door as otherwise it could be damaged.
Compressor placement
 Position the compressor within a distance of at least 500 mm from the cabinet to facilitate the
movement of the hoses and the power cord within the cabinet (Fig. 19).
Fig. 19: Positioning of the compressor for connections
 Make the pneumatic connections per Chapter 11.1.
 Connect the condensate collection tank per Chapter 11.3.
 Route the pressure hose, the condensate drain hose, and the power cord through the opening
in the rear wall of the cabinet.
 Position the compressor at such a distance from the cabinet so the WINSTA connector can
make the electrical connection between the compressor and the cabinet (Fig. 13, Fig. 20).
NP-DK50 2V 50, 2x2V 110-AD-A-2_05-2022
42
INSTALLATION
05/2022