Herunterladen Diese Seite drucken

EKOM DK50 2V/50/M Benutzerhandbuch Seite 38

Vorschau ausblenden Andere Handbücher für DK50 2V/50/M:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

 Position the compressor within a distance of at least 500 mm from the cabinet to facilitate the
movement of the hoses and the power cord within the cabinet (Fig. 14).
Fig. 14: Positioning of the compressor for connections
 Make the pneumatic connections per Chapter 11.1.
 Connect the condensate collection tank per Chapter 11.3.
 Route the pressure hose, the condensate drain hose, and the power cord through the opening
in the rear wall of the cabinet.
 Position the compressor at such a distance from the cabinet so the WINSTA connector can
make the electrical connection between the compressor and the cabinet (Fig. 13, Fig. 15).
NP-DK50 2V 50, 2x2V 110-AD-A-2_05-2022
38
INSTALLATION
05/2022

Werbung

loading