Presence button (4)
Activates the
preSence program (set the para-
meter below the prOgramS menu
item)
Absence button (5)
Activates the
aBSence program
Press once:
•
Press twice:
•
Auto button (6)
To start the currently activated
program (selection below
menu / prOgramS)
Menu button / return (7)
Access to the main menu
In the main menu:
•
•
Info button/ child lock (8)
•
•
•
14
To activate the reduced mode (set
t-reDuceD below menu / Setup /
SettingS;
factory setting 19 °C)
To activate the antifreeze pro-
gram (factory setting 7 °C)
press briefl y: to go one step back
press long: to go back to the
operating mode (changes are
not saved)
In the operating mode: shows
information on the current pro-
gram
On activating the preSence and
aBSence programs –> setup of
the activation period (1–30 days)
If the button is pressed longer
than 5 seconds, child lock/acti-
vate lock is activated or deacti-
vated. The display displays the
vated. The display displays the
symbol
.
Display
Display switches on automatically when the
knob is moved or a button is pressed. To incre-
ase the life of the batteries, the display swit-
ches off if not used for a prolonged period.
a
Menu / back
b
Day of the week
c
Battery display
d
current time
e
Room temperature actual value
f
Activated program
g
Info / child lock / activate lock
h
Heating level:
Antifreeze
Reduced-level
Comfort-level
i
Heating phase
k
Room temperature setpoint
Functions / operation
Operating modes
AUTO mode – temperature regulation
In the automatic mode, the thermostat regu-
lates the room temperature or the tempera-
ture level of the radiator (towel warming) ac-
cording to the provided program by switching
the heating element on and off.
Press the auto button to start the activated
►
program (see menu - programs/activate
program).
The selected program (e.g P1, see above) is
displayed on the display.