If the temperature needs to be changed temporarily, you
can do this easily using the handwheel. The thermostat will
automatically return to the time-controlled program at the next
regular temperature change in the time program.
7.2.2 Manual mode (Manu)
In manual mode (Manu), the controller operates like a
conventional thermostat.
In manual mode, the controller remains at the set temperature
permanently. There are no automatic time-controlled changes in
temperature. Similarly, the thermostat does not react to sensors
indicating an open window.
7.2.3 Holiday/Party function (
In this operating mode (
perature remains at a fixed level for a
defined period (e.g. for the duration
of a party or holiday). After this time,
the controller automatically switches
back to automatic mode or central mode. The controller always
switches to central mode if it was in central mode before holiday/
party mode and holiday/party mode was activated by the central
control unit.
If a shutter contact or a window rotary handle sensor is
integrated into the system, the door/window position is also
taken into account during holiday/party mode. This means that
if a monitored door or window is opened, the open-window
temperature is selected for control purposes.
Setting holiday/party mode:
• Press the "Menu" button until the
display.
• Now rotate the handwheel until you reach the required time,
and confirm this with the OK button.