Manual operation
The channel will be switched on or off for 15 minutes.
Afterwards, normal operation will be continued for the
heating zone.
8.2
Activating/deactivating the pump control
If you want to use connection terminal (H) for control-
ling a heating pump, the heating zone can be switched
to pump control directly via the device. To do this, please
proceed as follows:
Press the select button (B) until the LED of chan-
•
nel 1 starts flashing green (see fig. 7).
If the LED of channel 1 starts flashing slowly, the
pump control is activated. If the LED of channel 1
starts flashing quickly, the pump control is deac-
tivated.
•
If you do not want to change any parameters, you
can exit the menu by pressing the select button
(B) briefly.
•
To switch the parameter from activated to de-
activated or from deactivated to activated, press
and hold down the select button (B) for at least
4 seconds.