8

Manual operation

8.1

Switch heating zones on/off

For installation and tests you can manually switch single
heating zones on or off. To switch single heating zones
on or off, please proceed as follows:
Select the required channel using the select but-
ton (B) (see fig. 7).
Press the select button until the LED (B) flashes
green three times.
The channel will be switched on or off for 15 minutes.
Afterwards, normal operation will be continued for the
heating zone.
8.2

Activating/deactivating the pump control

If you want to use connection terminal (H) for controlling
a heating pump, the heating zone can be switched to
pump control directly via the device. To do this, proceed
as follows:
Press the select button (B) until the LED of chan-
nel 1 starts flashing green (see fig. 7).
If the LED of channel 1 starts flashing slowly, the
pump control is activated. If the LED of channel 1
Manual operation
71