Hazard information
The supply circuit has to be secured by a cable
protection switch in accordance with EN 60898-
1 (tripping characteristic B or C, max. 6 A rated
current, min. 6 KA interrupting rating, energy lim-
iting class 3).
The device has not been designed to support
safety disconnection.
Exceeding this capacity could lead to the de-
struction of the device, fires or electric shocks.
Before the actuator is connected, remove the
fuse from the fuse box.
Observe the installation instructions for installa-
tion in distribution systems (DIN VDE 0100-410).
The device may only be operated within domes-
tic environment, in business and trade areas as
well as in small enterprises.
Using the device for any purpose other than that
described in this operating manual does not fall
within the scope of intended use and shall invali-
date any warranty or liability.