Information on Converting the Device
11.1
Changing the concentration range to 6...10%
Where concentrations are greater than 5%, the maximum water flow rate must be reduced.
This entails replacing the flow regulator.
Flow value
360 l/h
840 l/h
Proceed as follows to change the concentration range:
Pull out the mains plug and interrupt the water infeed (close the angle valve).
Pull out plug (Item 1) and loosen nut (Item 2)
Loosen swivel nuts (Item 3), remove solenoid valve (Item 4)
Remove old flow regulator (Item 5) with a suitable tool
Insert the new flow regulator (Item 6). You must make sure that the new flow regulator is
positioned correctly (see Fig. 11.2 for the installation position).
Reinstall the solenoid valve in reverse order. Ensure that the flat seal is correctly seated.
Reconnect the electricity and water supply.
Check that the device is functioning properly and make sure that it is not leaking.
417102242_DG_3
Concentration range
max. 10 % (0.25-10%)
max. 5 % (0.25-5%)
Item
1
2
3
4
5
6
Fig. 11.1
Fig. 11.2
Flow regulator installation position
- 91 -
Comment
Separate accessory
Standard
Description
Plug
Nut
Swivel nut
Solenoid valve
Old flow regulator
New flow regulator
Corner valve retrofit
Rev.: 02-05.2014