8. TECHNICAL DATA
MultiPlus
PowerControl and PowerAssist
Transfer switch
INVERTER
Input voltage range
Output
Cont. output power at 25°C
Cont. output power at 25°C
Cont. output power at 40°C
Cont. output power at 65°C
Peak power
Maximum efficiency
Zero-load power
Zero-load power in search mode
CHARGER
AC Input
Charge voltage 'absorption'
Charge voltage 'float'
Storage mode
Charge current house battery
Charge current starter battery
Battery temperature sensor
GENERAL
VE.Bus communication port
Programmable relay (5)
Protection (2)
Common Characteristics
ENCLOSURE
Common Characteristics
Battery-connection
230V AC-connection
Weight
Dimensions (hxwxd)
STANDARDS
Safety
Emission / Immunity
Road vehicles
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
All manuals and user guides at all-guides.com
12 Volt
24 Volt
48 Volt
9,5 – 17V
(3)
Input frequency: 45 – 65Hz
(4)
1A (available on 12V and 24V models only)
Remote monitoring and system intergration
Material & Colour: Steel/ABS (blue RAL 5012)
EN 60335-1, EN 60335-2-29, EN 62109-1
EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3
3) Non-linear load, crest factor 3:1
4) At 25°C ambient
5) Programmable relay which can be set for general alarm,
DC undervoltage or genset start signal function
AC rating: 230V/4A
DC rating: 4A up to 35VDC, 1A up to 60VDC
12/800/35
24/800/16
48/800/9
Yes
16A
19 – 33V
Output voltage: 230 VAC ± 2%
Frequency: 50Hz ± 0,1% (1)
800VA
700W
650W
400W
1600W
92 / 93 / 94%
7 / 7 / 8W
2 / 2 / 3W
Input voltage range: 187-265VAC
Power factor: 1
14,4 / 28,8 / 57,6V
13,8 / 27,6 / 55,2V
13,2 / 26,4 /52,8V
35 / 16 / 9A
Yes
Yes
a – g
Operating temp. range: -40 to +65°C
(fan assisted cooling)
Humidity (non-condensing): max 95%
Protection category: IP21
25 / 16 / 10 mm²
G-ST18i connector
6,4kg
375 x 240 x 100mm
EN 50498
38– 66V
21