QUICK DRIVE PROGRAMMING
FUNCTION
1. Press and hold
the RAIL SYSTEM
button for 3 sec.
2. Short press of
/
helps to select
the track system
of your choice.
3. Short press of
confirms the
track system
selection
4. Long press
/
5. Long press
/
DESCRIPTION
All of the indicator lights are light up constantly for "SL,HL,VL" and
then off.
Then release the button until one
of the indicator lights flashes.
The corresponding LED will flash under the selected
SL, HL, VL type.
SL: Standard lift sectional doors with cylindrical cable
drum.
HL: High lift sectional doors with cylindrical-conical
cable
VL: Vertical lift sectional doors with conical cable
drum
The corresponded indicator light is constant
on for "SL,HL,VL"
Then, the digital display shows
setting.
Long press the button UP/DOWN to set the door to the target
OPEN limit position, then release the buttons.
Short Press the SET button once to store the open limit position,
the digital displays
Long press the button UP/DOWN to set the door to the target CLOSE limit
position then release the buttons.
Short press the SET button once to store the CLOSE limit position, then the
door drive will automatically open and close the door to store the door weight
and spring balance conditions.
Note:
a. If a system selection error occurs during the setting process, please click
Execute enter to exit the setting, and then execute the first
operation again.
b. Active or change any stand alone function, refer to the below "FUNCTION
TABLE MENU".
to start the OPEN travel limit
to start the CLOSE travel limit setting.
53