Bosch Rexroth AG
Stepper mode BASIC STEPPER
The changes will be with the programmed percentage values separate for each
weld time calculated.
At this will the formula %I = (scale units * 100 / 106) + 5,5 factored in.
All %I in scale units, changes in kA
The programed value default is invalid, because the relation of the current change
to the heat value change is unknown.
8.4.4

%I in kA and scale unit, change in %

Base value
%I change
Step_1
+10%
Step_2
+10%
Step_3
+10%
Step_4
+5%
Step_5
+5%
Welding programs can be used with the basic stepper, which in different weld
times have different control operation modes, because the percentage changes
be valid as well for kA as for scale units.
8.4.5
%I in kA and scale unit, change in %
The programed value default is invalid, because the relation of current change to
heat value modification is unknown.
R911336190 | PSI 6xCx.760.xx
PreWLD
MainWLD
30,00 scale
10,00kA
units
33,80 scale
11,00kA
units
37,18 scale
12,00kA
units
40,56 scale
13,00kA
units
42,25 scale
13,50kA
units
43,94 scale
14,00kA
units
PstWLD
7,00kA
7,70kA
8,40kA
9,10kA
9,45kA
9,80kA

Werbung