Fault
No CO
in the water, the button for car-
2
bonated water is not blocked
The serving amount of still water and
chilled water are too high.
The dispensed serving amount is not
correct for carbonated water.
Hot water partially escapes mixed with
steam
The control panel (buttons) does not
work after liquid has entered the de-
vice.
The water from the drip tray drains
badly.
The device does not work, no display,
one LED lights up blue
The device does not work, no display,
no LED lights up
E400: Replace the Active Pure filter
E401: Replace the Hy Protect filter
E404: Empty the drip tray. All red
LEDs light up.
E405: Empty the drain can . All red
LEDs light up.
E407: Disinfection necessary
E409: Replace the CO2 bottle
E410: Replacing the filter
E411: Filter running time exceeded
E412: Level sensor of carbonator de-
fective
E413: Check the water inlet
E500: Hot water malfunction. All red
LEDs light up
E501: Malfunction sanitisation, power
failure
E502: Malfunction water ingress in de-
vice. All red LEDs light up.
E503: Malfunction water ingress in
stand. All red LEDs light up.
E504: Malfunction buttons. All red
LEDs light up.
E505: Malfunction sanitisation sensor
hot
E506: Malfunction sanitisation sensor
cold
E507: Malfunction sanitisation sensor
ambient
E508: Malfunction heating module
overheating. All red LEDs light up.
24

Troubleshooting guide

Cause
The CO
bottle is almost empty.
2
The internal flowmeter is defective.
The compensation controller is set incorrectly.
The CO
pressure is wrong.
2
Location higher than 1500 m above sea level and max-
imum temperature setting (95 °C).
A container has tipped over on the top of the device.
The drip tray drain or the drain hose is contaminated.  Clean the drip tray.
No siphon in the waste water pipe (only for drain in
waste water pipe).
Insufficient height difference between drip tray and
waste water pipe (only for drain in waste water pipe).
The device is in sleep mode during timer operation.
The voltage supply is disturbed.
The device is switched off.
The safety fuse was triggered.
The Active Pure filter is used up.
The Hy Protect filter is used up.
The drip tray is full.
The drain can is full.
Sanitisation is due.
The CO
pressure is set too low.
2
The CO
bottle is empty.
2
The minimum water flow of chilled still water has not
been reached.
The maximum running time of a filter (device running
time) has been exceeded.
The automatic refilling of the CO
mixing tank has
2
failed.
No or insufficient water inlet.
The heating module is defective.
The sanitisation was not successful.
Leakage in the device.
Leakage in the stand.
Either the buttons have been pressed for too long or the
electronics have malfunctioned.
The sanitisation was not successful.
The sanitisation was not successful.
The sanitisation was not successful.
The water temperature in the hot water boiler is too
high.
Rectification
1. Open the door on the stand.
2. Observe the pressure gauge while dispensing carbonated water.
3. If the pressure drops significantly, replace the CO
 Call the Service.
 Set the compensation controller (see Chapter "User menu, operating
parameters, user settings/serving amount").
1. Check the CO
2. Readjust the serving amount on the adjusting wheel for the compensa-
tion controller (see Chapter "Operation/water dispensing').
 Set the hot water temperature lower or call the Service.
1. Set the power switch to "0".
2. Switch the device on again after 12 hours.
3. If this happens again, call the Service.
 Clean the drain hose.
 Install a siphon in the waste water pipe.
 Increase the height difference.
 Press and hold any button for more than 5 seconds.
 Plug the mains plug into the socket.
 Set the power switch to "1".
1. Pull out the fuse holder next to the power switch.
2. Replace the fuse with a new fuse (10 A, slow blow).
3. Insert the fuse holder again.
4. If it is triggered again, call the Service.
 Replace the Active Pure filter annually. Observe the menu instructions
of the device when doing this.
 Change the Hy Protect filter every 2 years. Observe the menu instruc-
tions of the device when doing this.
 Empty and clean the drip tray.
 Empty the drain can.
 Carry out a sanitisation.
 Set the CO
2
 Replace the CO
 Change the filter.
E400: Replace the Active Pure filter (annually)
 Change the filter.
E400: Replace the Active Pure filter (annually)
E401: Replace the Hy Protect filter (every 2 years)
1. Set the power switch to "0".
2. Set the power switch to "1".
3. Check the water connection.
4. Check the inlet screen.
5. Check the setting of the CO
6. If this happens again, call the Service.
1. Check the inlet screen in the water connection (see "Care and Service/
Clean the inlet screen").
2. Check the water connection.
3. Set the power switch to "0".
4. Set the power switch to "1".
5. If this happens again, call the Service.
1. Set the power switch to "0".
2. Call the Service.
 Start the sanitisation again.
1. Set the power switch to "0".
2. Call the Service.
1. Set the power switch to "0".
2. Call the Service.
1. Set the power switch to "0".
2. Set the power switch to "1".
3. If this happens again, call the Service.
1. Start the sanitisation again.
2. If this happens again, call the Service.
1. Start the sanitisation again.
2. If this happens again, call the Service.
1. Start the sanitisation again.
2. If this happens again, call the Service.
1. Set the power switch to "0".
2. Wait 10 minutes.
3. Set the power switch to "1".
4. If this happens again, call the Service.
English
pressure, adjust it according to the specification.
2
pressure to 3.0...3.5 bar when dispensing.
bottle.
2
pressure.
2
bottle.
2