GB
necessary, particularly the
Putting the compressor
wearing of suitable clothing and
into operation
masks.
The work room has to be
Assembling the wheels (1):
bigger than 30 m
3
and have
Fit the wheels as shown in
sufficient ventilation for
Figure 1.
spraying and drying. Never
1
spray into the wind.
It is always imperative to
observe the regulations of your
local police authorities when
spraying combustible or
hazardous substances.
Never process media such as
white petroleum spirit, butyl
alcohol and methylene chloride
with the PVC pressure hose
(reduced life span).
Assembling the rubber buffer
Fit the supplied rubber buffer to
Operation of pressure
the support foot as shown in
vessels in accordance
Figure 2.
with the pertinent
2
pressure vessel
regulations
1. An operator of a pressure
vessel is required to keep the
pressure vessel in good
working order, to operate it
properly, to supervise its use,
to carry out essential
maintenance and repair work
Replacing the oil filter and
immediately, and to introduce
installing the air filter (fig. 3)
essential safety measures
Use a screwdriver to remove the
according to requirements.
oil filler plug and insert the
2. The supervisory authorities
supplied stopper (2) in the
may order essential safeguards
opening.
from case to case.
Important! Check the oil level.
Screw the air filter (1) into the
3. A pressure vessel may not be
hole in the side of the compressor
operated if it has any defects
pump.
which constitute a danger to
3
employees or third parties.
4. The pressure vessel must be
regularly inspected for damage,
e.g. rust. If you discover any
damage, then please contact
the customer service
workshop.
10
05.07.2005
8:54 Uhr
Seite 10
Connecting to the power
supply:
The compressor is equipped with
a power cable and an earthing-pin
plug for connection to any 230 V
~ 50 Hz earthing-contact socket
outlet with a 16 A fuse. Long
supply lines, extensions, cable
reels and similar cause voltage
dips and may prevent the motor
from starting. Sluggishness
makes starting difficult at low
temperatures under freezing
point (0°C).
Explanation of the compressed
air fittings
1 Pressure switch
2 Safety valve
3 Pressure gauge (to indicate the
vessel pressure)
4 On/Off switch
4
Maintenance and
cleaning
Condensation water
Let out the condensation water
daily by opening the drain valve
(bottom of the pressure
vessel).
Safety valve
The safety valve is set to the
maximum pressure of the
pressure vessel. It is prohibited
to adjust the safety valve or to
remove its lead seal. Actuate
the safety valve from time to
time to ensure that it works
when required.