4-4. Changing the Settings (For output format F, and G only)
Any necessary changes to the settings can only be made for A/B signal output types.
For analog output type, always use with all switches in the OFF setting.
4-4-1. Changing the Direction
MODE switch 3 (Direction switch) is used to change the positional relationship of the A/B signal with
respect to the scale movement direction.
MODE switch 3
OFF
ON
For output format A, refer to section 4-5-1.
4-4-2. Changing the Resolution
MODE switch 6 (resolution setting switch) is used to change the resolution of the A/B signal output type.
In the case of output format F: ON = 0.1 µm
4-4
(E)
A
B
A
B
Table 4-2
OFF = 0.05 µm
Moves to head cable side
A signal is leading
B signal is leading
In the case of output format G: ON = 0.02 µm
OFF = 0.01 µm