Notes:
To minimize the measurement error caused by the distributed
capacitor, the testing lead or testing clip should be as short as
possible. When the tested capacitor is greater than 30 µF,
reading is for reference only.
Depending on the specifications of the capacitor and due to
the charging processes of the capacitor, it can take several
seconds until the final measuring result is displayed.
Capacitance Measurements - Accuracy
Range
6.6 µF
66 µF
660 µF
6.6 mF
66 mF
Overload protection: 250 V

Cleaning and Storing

Only clean the device with a soft moist cloth and allow it to
dry completely before the next use.
Do not use abrasives and aggressive chemicals.
If not in use, set the rotary function switch (13) to the "OFF"
position.
Remove the batteries from the unit if you do not use it for a
longer period of time.
Store the unit in a dry place that is protected from dust, dirt
and extreme temperatures.
Store the unit out of reach of children.
Operation
Resolution
0.001 µF
0.01 µF
0.1 µF
0.001 mF
0.01 mF
Accuracy
< 2 µF ± (4% of reading + 5 digits)
± (4% of reading + 3 digits)
or 250 V rms AC
62