Installation Instructions
Replacing the electronics
Promag 400 Index C
Instruction is valid for the following spare part kits:
Order number
Device component
Kit electronics module
complete Promag 400 C
Kit power supply
XPD0014-
Kit I/O-board
Kit amplifier
NOTICE
• The order number of the spare part set (on the packaging label) can differ from the product number (on the label directly on the spare part)!
• The order number of the relevant spare part set can be found by entering the product number of the spare part in the spare parts finder.
• We recommend that the Installation Instructions be kept with the packaging at all times.
Confirmation whether the spare part is permitted to be used with the measuring device
The spare parts set and Installation Instructions are used to replace a faulty unit with a functioning unit of the same type. Use genuine
parts from Endress+Hauser only. Only original spare parts supplied by Endress+Hauser shall be used with the measuring device.
Therefore, before use, check whether the spare part set is compatible with the measuring device.
A spare parts overview label is located in the connection compartment cover of the measuring device. If there is no label or the spare
part is not listed the appropriate spare part can also be identified via W@M Device Viewer.
How carrying out such a check via the W@M Device Viewer is described below:
Choose the Endress+Hauser Device Viewer via web browser: www.endress.com/deviceviewer
Enter the serial number (Ser. No.) of the device into the W@M Device Viewer (on the label of the transmitter), then click on "Spare parts".
The list of the available spare parts for the device is displayed.
Check the order number on the packaging label of the spare part set.
Check whether the order number of the spare part set is specified in the list displayed by the device viewer:
= YES, the spare part can be used.
= NO, the spare part may not be used.
If you have any questions, contact your Endress+Hauser service organization.
Products
Content of the spare part kit
1 × power supply, 1 × I/O-board, 1 × amplifier, 
1 × print carrier, terminal connections, 1 × ribbon cable, material for assembling
1 × power supply, 1 × terminal connection
1 × I/O-board, terminal connections
1 × amplifier, 1 × ribbon cable
2.
Ser . No.:12345
i
i
www.endress.com/deviceviewer
Solutions
1.
Device Viewer
Ser . No.:12345
4.
3.
=
?
5.
Services
A0016264

Werbung

loading

Inhaltszusammenfassung für Endress+Hauser Promag 400 Index C

  • Seite 1 The spare parts set and Installation Instructions are used to replace a faulty unit with a functioning unit of the same type. Use genuine parts from Endress+Hauser only. Only original spare parts supplied by Endress+Hauser shall be used with the measuring device.
  • Seite 2 1, 2, 3 1 Trained customer technician 2 Service technician authorized by Endress+Hauser 3 Endress+Hauser (send measuring device back to manufacturer) Safety instructions • Check whether the spare part matches the identification label on • After removing the electronics cover, there is a risk of electric shock the measuring device, as explained on the first page.
  • Seite 3 Replacing the electronics A Disassembly the electronics complete A.1 without connection board Unplug the T-DAT (graphic 4 below) from the current electronics and plug it in the new electronics. Check wheter the S-DAT is inside of the sensor interface (graphic 9). A0021991 A0021571 A0021572...
  • Seite 4 Replacing the electronics B Re-assembly Re-assembly is carried out in reverse order, unless otherwise instructed.. HINWEIS HINWEIS B1. For electronics with connectionboard: B3. For electronics with connectionboard and without connectionboard: Before assembling the amplifier board remove the jumperƒn (graphic 1 below ). Otherwise remove the S-DAT out of the defect amplifier board Ensure that the S-DAT inside of the connection board is plugged in (graphic 1 below) and assemble it into the new amplifier board...
  • Seite 5 Replacing the electronics C Replacing the amplifier board Procedure as in chapter A, graphic 1 - 6. D Replacing the power supply Procedure as in chapter A, graphic 1 - 8. A0022409 E Replacing the I/O-module Procedure as in chapter A, graphic 1 - 8.
  • Seite 6 Replacing the electronics F Re-assembly Re-assembly is carried out in reverse order, unless otherwise instructed.. HINWEIS HINWEIS B1. For electronics with connectionboard: B3. For electronics with connectionboard and without connectionboard: Before assembling the amplifier board remove the jumperƒn (graphic 1 below ). Otherwise remove the S-DAT out of the defect amplifier board Ensure that the S-DAT inside of the connection board is plugged in (graphic 1 below) and assemble it into the new amplifier board...
  • Seite 7 Es dürfen nur Originalteile von Endress+Hauser verwendet werden. Grundsätzlich dürfen nur Ersatzteilsets verwendet werden, die von Endress+Hauser für das Messgerät vorgesehen sind. Vor der Verwendung ist deshalb zu überprüfen, ob das Ersatzteilsets zum Messgerät passt. Im Anschlussraumdeckel des Messgeräts befindet sich ein Übersichtsschild Ersatzteile. Falls dieses nicht vorhanden oder das Ersatzteilset nicht aufgelistet ist, kann eine solche Überprüfung via W@M Device Viewer durchgeführt werden.
  • Seite 8 Zulassung (z.B. IECEx, ATEX, CSA) 1, 2, 3 1 Ausgebildete Fachkraft des Kunden 2 Von Endress+Hauser autorisierter Servicetechniker 3 Endress+Hauser (Messgerät an Hersteller zurücksenden) Sicherheitshinweise • Prüfen, ob das vorliegende Ersatzteil zur Kennzeichnung auf • Nach Entfernen der Elektronikabdeckung: Stromschlaggefahr dem Messgerät passt, wie auf der Titelseite beschrieben.
  • Seite 9 Austausch Elektronik A Austausch Elektronik komplett A.1 ohne Anschlussprint Den vorhandenen T-Dat (Bild 4 unten) aus der bestehenden Elektronik herausziehen und den T-Dat in die neue Elektronik einstecken. Kontrollieren ob der S-DAT in der Sensorschnittstelle vorhanden ist (Bild 9). A0021991 A0021571 A0021572 3 mm...
  • Seite 10 Austausch Elektronik B Zusammenbau Der Zusammenbau erfolgt in umgekehrter Reihenfolge, wenn nicht anders angegeben. HINWEIS HINWEIS B1. Für Elektronik mit Anschlussprint: B3. Für Elektronik mit Anschlussprint und für Elektronik ohne Anschlussprint: Vor dem Einbau des Messverstärkers muss der Jumper  (Bild 1 unten) entfernt werden.
  • Seite 11 Austausch Elektronik C Austausch Verstärker Vorgehen wie in Kapitel A, Bild 1 - 6. D Austausch Netzteil Vorgehen wie in Kapitel A, Bild 1 - 8. A0022409 E Austausch I/O-Modul Vorgehen wie in Kapitel A, Bild 1 - 8. A0022549 Endress + Hauser...
  • Seite 12 Austausch Elektronik F Zusammenbau Der Zusammenbau erfolgt in umgekehrter Reihenfolge, wenn nicht anders angegeben. HINWEIS HINWEIS F1. Für Elektronik mit Anschlussprint: F3. Für Elektronik mit Anschlussprint und für Elektronik ohne Anschlussprint: Vor dem Einbau des Messverstärkers muss der Jumper  (Bild 1 unten) entfernt werden.