Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Napoleon Stylus Steinfeld Installations- Und Betriebshandbuch

Elektrischer kamin zur wandmontage
Vorschau ausblenden Andere Handbücher für Stylus Steinfeld:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

WARNING
!
Turn off the appliance completely and let cool before servicing. Only a qualifi ed service person should service
and repair this electric appliance.
symptom
Appliance will not
Appliance is not plugged into an
come on when
electrical outlet.
power button/
Appliance has overheated
switch is put into
and safety thermal switch has
the "on" position.
tripped.
Main PCB board issue.
Appliance turns
House circuit breaker has
off and will not
tripped.
turn on.
Appliance's fuse has blown.
Appliance has overheated
and safety thermal switch has
tripped.
Appliance has
Power failure.
returned to default
settings.
Remote control
Low/dead batteries.
does not work.
Remote receiver malfunction.
No warm air
Heater setting not selected.
coming out of the
Heater has been locked out.
appliance.
Room temperature is higher than
appliance setting (if set to room
temperature).
Appliance has overheated
and safety thermal switch has
tripped.
Heater issue.
Heater shuts off
Room is too warm.
automatically.
Dim or no fl ame.
Flame brightness not selected.
Flame LEDs issue.
Main PCB board issue.
Flame does not
Motor is stalled/malfunctioning.
move.
problem
Check plug, and plug in the appliance if necessary.
Unplug power or turn off the circuit breaker, allow appliance
to cool for 15 minutes, then plug in the appliance or turn the
breaker on.
Inspect the circuit board and replace, if necessary.
Reset house circuit breaker.
Replace the fuse.
Unplug power or turn off the circuit breaker, allow appliance to
cool for 15 minutes to reset the thermal switch, then plug in the
appliance or turn the breaker on.
Re-program appliance to original settings (not applicable with all
appliances).
Replace batteries in remote control.
Ensure remote receiver is not blocked. Replace control panel.
See "operation" section.
See "operation" section.
Reset temperature setting.
Unplug power or turn off the circuit breaker. Allow for appliance
to cool for 15 minutes.
Inspect the blower and heater and replace, if necessary.
The heater has a built-in thermostat so it will shut off
automatically once the pre-set temperature is reached. It will
also turn on automatically if the room temperature drops below
the pre-set temperature.
See "operation" section.
Inspect the LED and replace, if necessary.
Inspect the main PCB board and replace, if necessary.
Cycle on/off. If problem persists, consult dealer.

6.0 troubleshooting

solution
W415-3032 / A / 10.29.21
EN
21

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Nefp32-5320bw-eu

Inhaltsverzeichnis