Pin
Wire color
s Sender
10
Violet
Device communication (EFI
11
Gray/pink
Reserved
FE
Green
Functional earth
Pin assignment for extension connection C4000 Entry/Exit M26 × 11 + FE
Pin
Wire color
s Sender
1
Brown
24 V DC output (voltage supply)
2
Blue
0 V DC (voltage supply)
3
Gray
Reserved
4
Pink
Reserved
5
Red
Reserved
6
Yellow
Reserved
7
White
Reserved
8
Red/blue
Reserved
9
Black
Device communication (EFI
10
Violet
Device communication (EFI
11
Gray/pink
Do not use
FE
Green
Functional earth
Extension connection M12 × 7 + FE
4
FE
5
6
3
2
1
7
Pin assignment for extension connection C4000 Standard and C4000 Advanced M12 × 7 + FE
Pin
Wire color
s Sender
1
White
Output for Host/Guest SEL
2
Brown
24 V DC output (voltage supply)
3
Green
Device communication (EFI
4
Yellow
Device communication (EFI
5
Gray
Reserved
6
Pink
Reserved
7
Blue
0 V DC (voltage supply)
FE
Shield
Functional earth
r Receiver
)
Device communication (EFI
B
Reserved
Functional earth
r Receiver
24 V DC output (voltage supply)
0 V DC (voltage supply)
Input for emergency stop 1
Input for emergency stop 2
Reset/restart
Test output for emergency stop 2
Test output for emergency stop 1
Output for reset required
)
Device communication (EFI
A
)
Device communication (EFI
B
Do not use
Functional earth
2
FE
3
4
1
7
6
5
r Receiver
Output for Host/Guest SEL
24 V DC output (voltage supply)
)
Device communication (EFI
A
)
Device communication (EFI
B
Reserved
Reserved
0 V DC (voltage supply)
Functional earth
8028265/2023-03-23 | SICK