Herunterladen Inhalt Inhalt Diese Seite drucken

Temperature-Controlled Charging - Fronius Selectiva 4.0 UL B1 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Program
1
2
3
4
5
In each of these programs, the solenoid valve picks up for an "ON 1" time and
drops out for an "OFF 1" time. This process repeats as many times as specified
for "Repeat". After this number of repetitions has elapsed, the "ON 2" and "OFF
2" times continue until the end of charging.
Temperature-

Temperature-controlled charging:

controlled char-
ging
The following settings are available for temperature-controlled charging:
automatic/OFF/required
-
-
-
Error overtemperature ON/OFF
-
-
Warning overtemperature ON/OFF
-
-
For certain curves, an external temperature sensor is required. If such a curve is
selected in configuration mode, a message is displayed indicating that an external
temperature sensor is required.
The following curves require an external temperature sensor:
-
-
ON 1
30 min
3 min
3 min
5 min
2,5 min
automatic ... Temperature-dependent adjustment of the charging curve.
OFF ... The measured battery temperature is not taken into account.
required ...
Charging only starts when the temperature sensor is connected.
ON ... An error message is output in the event of a battery overtemperature.
The charging process stops and can only be continued after the battery has
cooled down and been reconnected.
OFF ... No error message in the event of a battery overtemperature.
ON ... A warning is output in the event of a battery overtemperature.
OFF ... No warning in the event of a battery overtemperature.
28 - FCC IUI - CSM WET
30 - FCC IUI - WET
OFF 1
Repeat
25 min
1 x
10 min
4 x
12 min
1 x
10 min
3 x
7,5 min
1 x
(not available with the Selectiva UL
version)
ON 2
OFF 2
5 min
25 min
3 min
20 min
3 min
12 min
5 min
20 min
2,5 min
7,5 min
47

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Selectiva 4.0 ul c1

Inhaltsverzeichnis